2021Han LocalConstraints

From 3DEM-Methods
Revision as of 08:28, 11 June 2021 by WikiSysop (talk | contribs) (Created page with "== Citation == Han, R.; Li, G. & Gao, X. Robust and ultrafast fiducial marker correspondence in electron tomography by a two-stage algorithm considering local constraints...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Citation

Han, R.; Li, G. & Gao, X. Robust and ultrafast fiducial marker correspondence in electron tomography by a two-stage algorithm considering local constraints. Bioinformatics, 2021, 37, 107-117

Abstract

Motivation
Electron tomography (ET) has become an indispensable tool for structural biology studies. In ET, the tilt series alignment and the projection parameter calibration are the key steps toward high-resolution ultrastructure analysis. Usually, fiducial markers are embedded in the sample to aid the alignment. Despite the advances in developing algorithms to find correspondence of fiducial markers from different tilted micrographs, the error rate of the existing methods is still high such that manual correction has to be conducted. In addition, existing algorithms do not work well when the number of fiducial markers is high.

Results
In this article, we try to completely solve the fiducial marker correspondence problem. We propose to divide the workflow of fiducial marker correspondence into two stages: (i) initial transformation determination, and (ii) local correspondence refinement. In the first stage, we model the transform estimation as a correspondence pair inquiry and verification problem. The local geometric constraints and invariant features are used to reduce the complexity of the problem. In the second stage, we encode the geometric distribution of the fiducial markers by a weighted Gaussian mixture model and introduce drift parameters to correct the effects of beam-induced motion and sample deformation. Comprehensive experiments on real-world datasets demonstrate the robustness, efficiency and effectiveness of the proposed algorithm. Especially, the proposed two-stage algorithm is able to produce an accurate tracking within an average of  ⩽ 100 ms per image, even for micrographs with hundreds of fiducial markers, which makes the real-time ET data processing possible.<p>Availability and implementation
The code is available at https://github.com/icthrm/auto-tilt-pair. Additionally, the detailed original figures demonstrated in the experiments can be accessed at https://rb.gy/6adtk4.

Keywords

Links

https://academic.oup.com/bioinformatics/article-abstract/37/1/107/6069572

Related software

Related methods

== Comments ==