<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2003Fernandez_AND</id>
	<title>2003Fernandez AND - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2003Fernandez_AND"/>
	<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2003Fernandez_AND&amp;action=history"/>
	<updated>2026-05-24T20:36:35Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.2</generator>
	<entry>
		<id>https://3demmethods.i2pc.es/index.php?title=2003Fernandez_AND&amp;diff=1873&amp;oldid=prev</id>
		<title>Jjfdez at 13:39, 22 May 2009</title>
		<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2003Fernandez_AND&amp;diff=1873&amp;oldid=prev"/>
		<updated>2009-05-22T13:39:36Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Citation ==&lt;br /&gt;
Fernández JJ, Li S. An improved algorithm for anisotropic nonlinear diffusion for denoising cryo-tomograms. J Struct Biol. 2003 144(1-2):152-161.&lt;br /&gt;
&lt;br /&gt;
== Abstract ==&lt;br /&gt;
Cryo-electron tomography is an imaging technique with an unique potential for visualizing large complex biological specimens. It ensures preservation of the biological material but the resulting cryotomograms are extremely noisy. Sophisticated denoising techniques are thus essential for allowing the visualization and interpretation of the information contained in the cryotomograms. Here a software tool based on anisotropic nonlinear diffusion is described for filtering cryotomograms. The approach reduces local noise and meanwhile enhances both curvilinear and planar structures. In the program a novel solution of the partial differential equation has been implemented, which allows a reliable estimation of derivatives and, furthermore, reduces computation time and memory requirements. Several criteria have been included to automatically select the optimal stopping time. The behaviour of the denoising approach is tested for visualizing filamentous structures in cryotomograms.&lt;br /&gt;
&lt;br /&gt;
== Keywords ==&lt;br /&gt;
Electron tomography; Denoising; Anisotropic nonlinear diffusion&lt;br /&gt;
&lt;br /&gt;
== Links ==&lt;br /&gt;
Article: http://dx.doi.org/10.1016/j.jsb.2003.09.010    &lt;br /&gt;
&lt;br /&gt;
== Related software ==&lt;br /&gt;
[http://www.ual.es/~jjfdez/SW/tomoand.html TOMOAND]&lt;br /&gt;
&lt;br /&gt;
== Related methods ==&lt;br /&gt;
&lt;br /&gt;
== Comments ==&lt;/div&gt;</summary>
		<author><name>Jjfdez</name></author>
	</entry>
</feed>