<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2007Castano_alignment</id>
	<title>2007Castano alignment - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2007Castano_alignment"/>
	<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2007Castano_alignment&amp;action=history"/>
	<updated>2026-05-24T20:36:23Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.2</generator>
	<entry>
		<id>https://3demmethods.i2pc.es/index.php?title=2007Castano_alignment&amp;diff=1981&amp;oldid=prev</id>
		<title>Jjfdez at 08:48, 7 August 2009</title>
		<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2007Castano_alignment&amp;diff=1981&amp;oldid=prev"/>
		<updated>2009-08-07T08:48:44Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Citation ==&lt;br /&gt;
&lt;br /&gt;
Castaño-Díez D, Al-Amoudi A, Glynn AM, Seybert A, Frangakis AS. Fiducial-less alignment of cryo-sections. J Struct Biol. 2007 Sep;159(3):413-23&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Abstract ==&lt;br /&gt;
&lt;br /&gt;
Cryo-electron tomography of vitreous sections is currently the most promising technique for visualizing arbitrary regions of eukaryotic cells or tissue at molecular resolution. Despite significant progress in the sample preparation techniques over the past few years, the three dimensional reconstruction using electron tomography is not as simple as in plunge frozen samples for various reasons, but mainly due to the effects of irradiation on the sections and the resulting poor alignment. Here, we present a new algorithm, which can provide a useful three-dimensional marker model after investigation of hundreds to thousands of observations calculated using local cross-correlation throughout the tilt series. The observations are chosen according to their coherence to a particular model and assigned to virtual markers. Through this type of measurement a merit figure can be calculated, precisely estimating the quality of the reconstruction. The merit figures of this alignment method are comparable to those obtained with plunge frozen samples using fiducial gold markers. An additional advantage of the algorithm is the implicit detection of areas in the sections that behave as rigid bodies and can thus be properly reconstructed.&lt;br /&gt;
&lt;br /&gt;
== Keywords ==&lt;br /&gt;
&lt;br /&gt;
Electron tomography; Image processing; CEMOVIS&lt;br /&gt;
&lt;br /&gt;
== Links ==&lt;br /&gt;
&lt;br /&gt;
Article http://dx.doi.org/10.1016/j.jsb.2007.04.014    &lt;br /&gt;
&lt;br /&gt;
== Related software ==&lt;br /&gt;
&lt;br /&gt;
== Related methods ==&lt;br /&gt;
&lt;br /&gt;
== Comments ==&lt;/div&gt;</summary>