<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2018Koeck_PhaseShift</id>
	<title>2018Koeck PhaseShift - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2018Koeck_PhaseShift"/>
	<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2018Koeck_PhaseShift&amp;action=history"/>
	<updated>2026-05-24T22:00:55Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.2</generator>
	<entry>
		<id>https://3demmethods.i2pc.es/index.php?title=2018Koeck_PhaseShift&amp;diff=3238&amp;oldid=prev</id>
		<title>WikiSysop: Created page with &quot;== Citation ==  Koeck, P. J. B. Design of an electrostatic phase shifting device for biological transmission electron microscopy. Ultramicroscopy, 2018, 187, 107-112  == Abstr...&quot;</title>
		<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2018Koeck_PhaseShift&amp;diff=3238&amp;oldid=prev"/>
		<updated>2018-03-20T17:46:35Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;== Citation ==  Koeck, P. J. B. Design of an electrostatic phase shifting device for biological transmission electron microscopy. Ultramicroscopy, 2018, 187, 107-112  == Abstr...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Citation ==&lt;br /&gt;
&lt;br /&gt;
Koeck, P. J. B. Design of an electrostatic phase shifting device for biological transmission electron microscopy. Ultramicroscopy, 2018, 187, 107-112&lt;br /&gt;
&lt;br /&gt;
== Abstract ==&lt;br /&gt;
&lt;br /&gt;
I suggest an electrostatic phase plate designed to broaden the contrast transfer function of a transmission electron microscope operated close to Scherzer defocus primarily in the low resolution direction. At higher defocus the low frequency behavior is equal to that close to Scherzer defocus, but CTF-correction becomes necessary to extend image interpretation to higher resolution. One simple realization of the phase plate consists of two ring shaped electrodes symmetrically surrounding the central beam. Since no physical components come into contact with the central beam and charge on the electrodes is controlled by an external voltage supply, problems with uncontrolled charging are expected to be reduced.&lt;br /&gt;
&lt;br /&gt;
== Keywords ==&lt;br /&gt;
&lt;br /&gt;
== Links ==&lt;br /&gt;
&lt;br /&gt;
https://www.sciencedirect.com/science/article/pii/S030439911730270X&lt;br /&gt;
&lt;br /&gt;
== Related software ==&lt;br /&gt;
&lt;br /&gt;
== Related methods ==&lt;br /&gt;
&lt;br /&gt;
== Comments ==&lt;/div&gt;</summary>
		<author><name>WikiSysop</name></author>
	</entry>
</feed>