<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2018Neumann_validation</id>
	<title>2018Neumann validation - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2018Neumann_validation"/>
	<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2018Neumann_validation&amp;action=history"/>
	<updated>2026-05-24T20:15:57Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.2</generator>
	<entry>
		<id>https://3demmethods.i2pc.es/index.php?title=2018Neumann_validation&amp;diff=3259&amp;oldid=prev</id>
		<title>WikiSysop: Created page with &quot;== Citation ==  Neumann, P.; Dickmanns, A. &amp; Ficner, R. Validating Resolution Revolution. Structure, 2018   == Abstract == Recent advances in instrumentation and image-process...&quot;</title>
		<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2018Neumann_validation&amp;diff=3259&amp;oldid=prev"/>
		<updated>2018-04-30T10:04:18Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;== Citation ==  Neumann, P.; Dickmanns, A. &amp;amp; Ficner, R. Validating Resolution Revolution. Structure, 2018   == Abstract == Recent advances in instrumentation and image-process...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Citation ==&lt;br /&gt;
&lt;br /&gt;
Neumann, P.; Dickmanns, A. &amp;amp; Ficner, R. Validating Resolution Revolution. Structure, 2018 &lt;br /&gt;
&lt;br /&gt;
== Abstract ==&lt;br /&gt;
Recent advances in instrumentation and image-processing software have resulted in a resolution revolution in cryo-electron microscopy (cryo-EM) and a surge in the popularity of this technique. However, despite technical progress and hundreds of structures determined so far, development of standards assessing the agreement between the cryo-EM map and the respective model has fallen behind. Here we establish a validation procedure evaluating this agreement and applied it to a set of 565 cryo-EM structures. Analysis of the results revealed that three-quarters of the validated structures exhibit moderate or low agreement between the map and the corresponding model, mostly due to limited structural features possessed by these maps. Model re-refinement significantly improved the agreement for only one-fifth of the structures, reaffirming the necessity to re-evaluate map resolution. The presented procedure provides an approach to re-estimate the resolution of cryo-EM map areas interpreted by the model. &lt;br /&gt;
&lt;br /&gt;
== Keywords ==&lt;br /&gt;
&lt;br /&gt;
== Links ==&lt;br /&gt;
&lt;br /&gt;
https://www.cell.com/structure/abstract/S0969-2126(18)30084-4&lt;br /&gt;
&lt;br /&gt;
== Related software ==&lt;br /&gt;
&lt;br /&gt;
== Related methods ==&lt;br /&gt;
&lt;br /&gt;
== Comments ==&lt;/div&gt;</summary>
		<author><name>WikiSysop</name></author>
	</entry>
</feed>