<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2026Motta_Dublins</id>
	<title>2026Motta Dublins - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://3demmethods.i2pc.es/index.php?action=history&amp;feed=atom&amp;title=2026Motta_Dublins"/>
	<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2026Motta_Dublins&amp;action=history"/>
	<updated>2026-07-23T21:38:17Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.2</generator>
	<entry>
		<id>https://3demmethods.i2pc.es/index.php?title=2026Motta_Dublins&amp;diff=5234&amp;oldid=prev</id>
		<title>WikiSysop: Created page with &quot;== Citation ==  Motta Alves, G., Andrews, T., McBean, P., Wells, T., El-Gomati, M.M., Burkhalter, S., Schulze-Briese, C., Zambon, P., McMullan, G., Henderson, R. and others 2026. The Dublin lens: a Cc= 1.0 mm objective lens intended for CryoEM at 100 keV. Methods in Microscopy. 3, 1 (2026), 19–25.  == Abstract ==  We have designed, fabricated and tested a lens with a chromatic aberration coefficient (Cc) of 1.0 mm, a 4.0 mm pole-gap and 2.0 mm bore that is wide enough...&quot;</title>
		<link rel="alternate" type="text/html" href="https://3demmethods.i2pc.es/index.php?title=2026Motta_Dublins&amp;diff=5234&amp;oldid=prev"/>
		<updated>2026-07-23T06:19:35Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;== Citation ==  Motta Alves, G., Andrews, T., McBean, P., Wells, T., El-Gomati, M.M., Burkhalter, S., Schulze-Briese, C., Zambon, P., McMullan, G., Henderson, R. and others 2026. The Dublin lens: a Cc= 1.0 mm objective lens intended for CryoEM at 100 keV. Methods in Microscopy. 3, 1 (2026), 19–25.  == Abstract ==  We have designed, fabricated and tested a lens with a chromatic aberration coefficient (Cc) of 1.0 mm, a 4.0 mm pole-gap and 2.0 mm bore that is wide enough...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Citation ==&lt;br /&gt;
&lt;br /&gt;
Motta Alves, G., Andrews, T., McBean, P., Wells, T., El-Gomati, M.M., Burkhalter, S., Schulze-Briese, C., Zambon, P., McMullan, G., Henderson, R. and others 2026. The Dublin lens: a Cc= 1.0 mm objective lens intended for CryoEM at 100 keV. Methods in Microscopy. 3, 1 (2026), 19–25.&lt;br /&gt;
&lt;br /&gt;
== Abstract ==&lt;br /&gt;
&lt;br /&gt;
We have designed, fabricated and tested a lens with a chromatic aberration coefficient (Cc) of 1.0 mm, a 4.0 mm pole-gap and 2.0 mm bore that is wide enough to accommodate an anti-contamination system and an objective aperture. This lens extends the temporal-coherence envelope of the electron microscope beyond 2 Å, using a low-cost Schottky FEG. We hope that this lens design can be used to improve all 100 keV electron microscopes designed for single-particle electron cryomicroscopy (cryoEM).&lt;br /&gt;
&lt;br /&gt;
== Keywords ==&lt;br /&gt;
&lt;br /&gt;
== Links ==&lt;br /&gt;
&lt;br /&gt;
https://www.degruyterbrill.com/document/doi/10.1515/mim-2025-0019/html&lt;br /&gt;
&lt;br /&gt;
== Related software ==&lt;br /&gt;
&lt;br /&gt;
== Related methods ==&lt;br /&gt;
&lt;br /&gt;
== Comments ==&lt;/div&gt;</summary>
		<author><name>WikiSysop</name></author>
	</entry>
</feed>