2004Sorzano IDR: Difference between revisions

From 3DEM-Methods
Jump to navigation Jump to search
No edit summary
 
No edit summary
Line 1: Line 1:
== Citation ==
== Citation ==


Sorzano, C. O. S.; Marabini, R.; Herman, G. T.; Censor, Y. & Carazo, J. M. Transfer function restoration in 3D electron microscopy via iterative data refinement Physics in Medicine & Biology, 2004, 49, 509-522
<tt>
<tt>
  '''BibTex'''
  '''BibTex'''


Sorzano, C. O. S.; Marabini, R.; Herman, G. T.; Censor, Y. & Carazo, J. M. Transfer function restoration in 3D electron microscopy via iterative data refinement Physics in Medicine & Biology, 2004, 49, 509-522
   @ARTICLE{Sorzano2004b,
   @ARTICLE{Sorzano2004b,
     author = {Sorzano, C. O. S. and Marabini, R. and Herman, G. T. and Censor,
     author = {Sorzano, C. O. S. and Marabini, R. and Herman, G. T. and Censor,

Revision as of 07:11, 1 April 2009

Citation

Sorzano, C. O. S.; Marabini, R.; Herman, G. T.; Censor, Y. & Carazo, J. M. Transfer function restoration in 3D electron microscopy via iterative data refinement Physics in Medicine & Biology, 2004, 49, 509-522

BibTex
 @ARTICLE{Sorzano2004b,
   author = {Sorzano, C. O. S. and Marabini, R. and Herman, G. T. and Censor,
            Y. and Carazo, J. M.},
   title = {Transfer function restoration in 3{D} electron microscopy via iterative
            data refinement},
   journal = {Physics in Medicine and Biology},
   year = {2004},
   volume = {49},
   pages = {509-522}
 }

Cited by

Abstract

Three-dimensional electron microscopy (3D-EM) is a powerful tool for visualizing complex biological systems. As with any other imaging device, the electron microscope introduces a transfer function (called in this field the contrast transfer function, CTF) into the image acquisition process that modulates the various frequencies of the signal. Thus, the 3D reconstructions performed with these CTF-affected projections are also affected by an implicit 3D transfer function. For high-resolution electron microscopy, the effect of the CTF is quite dramatic and limits severely the achievable resolution. In this work we make use of the iterative data refinement (IDR) technique to ameliorate the effect of the CTF. It is demonstrated that the approach can be successfully applied to noisy data.

Keywords

CTF restoration

Links

Article http://math.haifa.ac.il/yair/PMBfinalaccepted041203.pdf

Related software

Xmipp: http://xmipp.cnb.csic.es/twiki/bin/view/Xmipp/IDR_ART

Related methods

Comments