1982Schiske Correction
Jump to navigation
Jump to search
Citation
Schiske, P. A posteriori correction of object tilt for the CTEM. Ultramicroscopy, 1982, 9, 17-26
Abstract
The imaging of tilted objects in a CTEM is treated from the point of view of a posteriori correction (e.g. as preliminary step for 3D reconstruction). Strictly periodic as well as thin objects of a more general type are discussed. For weak thin objects a new a posteriori correction of tilt is proposed.
Keywords
CTF correction, tilted specimens
Links