2014Voortman LimitingFactors

From 3DEM-Methods
Jump to navigation Jump to search

Citation

Voortman, L. M.; Vulović, M.; Maletta, M.; Voigt, A.; Franken, E. M.; Simonetti, A.; Peters, P. J.; van Vliet, L. J. & Rieger, B. Quantifying resolution limiting factors in subtomogram averaged cryo-electron tomography using simulations. J Struct Biol, 2014, 187, 103-111

Abstract

Cryo-electron tomography (CET) is the only available technique capable of characterizing the structure of biological macromolecules in conditions close to the native state. With the advent of subtomogram averaging, as a post-processing step to CET, resolutions in the (sub-) nanometer range have become within reach. In addition to advances in instrumentation and experiments, the reconstruction scheme has improved by inclusion of more accurate contrast transfer function (CTF) correction methods, better defocus estimation, and better alignments of the tilt-series and subtomograms. To quantify the importance of each contribution, we have split the full process from data collection to reconstruction into different steps. For the purpose of evaluation we have acquired tilt-series of ribosomes in such a way that we could precisely determine the defocus of each macromolecule. Then, we simulated tilt-series using the InSilicoTEM package and applied tomogram reconstruction and subtomogram averaging. Through large scale simulations under different conditions and parameter settings we find that tilt-series alignment is the resolution limiting factor for our experimental data. Using simulations, we find that when this alignment inaccuracy is alleviated, tilted CTF correction improves the final resolution, or equivalently, the same resolution can be achieved using less particles. Furthermore, we predict from which resolution onwards better CTF correction and defocus estimation methods are required. We obtain a final average using 3198 ribosomes with a resolution of 2.2nm on the experimental data. Our simulations suggest that with the same number of particles a resolution of 1.2nm could be achieved by improving the tilt-series alignment.

Keywords

Links

http://www.ncbi.nlm.nih.gov/pubmed/24998892

Related software

Related methods

Comments