2004Volkmann ParticlePicking

From 3DEM-Methods
Revision as of 08:19, 20 May 2013 by CoSS (talk | contribs) (Created page with "== Citation == Volkmann, N. An approach to automated particle picking from electron micrographs based on reduced representation templates J. Structural Biology, 2004, 145, 15...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Citation

Volkmann, N. An approach to automated particle picking from electron micrographs based on reduced representation templates J. Structural Biology, 2004, 145, 152-156

Abstract

Reduced representation templates are used in a real-space pattern matching framework to facilitate automatic particle picking from electron micrographs. The procedure consists of five parts. First, reduced templates are constructed either from models or directly from the data. Second, a real-space pattern matching algorithm is applied using the reduced representations as templates. Third, peaks are selected from the resulting score map using peak-shape characteristics. Fourth, the surviving peaks are tested for distance constraints. Fifth, a correlation-based outlier screening is applied. Test applications to a data set of keyhole limpet hemocyanin particles indicate that the method is robust and reliable.

Keywords

Automatic particle picking.

Links

http://www.ncbi.nlm.nih.gov/pubmed/15065682

Related software

Related methods

Comments